Select a method to open its work instruction or development status.
8 METHODS
TEST 01Ash ContentInternal method · IC-AM-001
TEST 02MoistureASTM D1509
TEST 03Iodine NumberASTM D1510
TEST 04OAN / Oil AdsorptionASTM D2414
TEST 05Methylene Blue ValueMethod confirmation pending
TEST 06Surface AreaASTM D6556
TEST 07Bulk DensityMethod confirmation pending
TEST 08Sieve ResidueASTM D1514
Method integrity note. The Ash Content guide currently uses Indigo's selected 750°C / 5-hour internal method. It is a modified method based on ASTM D1506 and must not be represented as ASTM D1506-compliant. All eight method modules are available to explore. Each has a separate guided test session; unresolved method details remain clearly flagged inside the relevant module.
MODULE 01
Equipment Register
Laboratory equipment inventory and technical reference.
MODULE 02
Test Procedures & Visual Guides
Controlled work instructions for laboratory personnel.
Iodine adsorption with titration or validated automated analysis.
ASTM D1510
◉
METHOD MODULE
OAN / Oil Adsorption
Oil absorption number using absorptometer endpoint detection.
ASTM D2414
◉
METHOD MODULE
Methylene Blue Value
Adsorption method module; method validation status is explained inside.
IC-MBV
◉
METHOD MODULE
Surface Area
NSA / STSA measurement using gas adsorption instrumentation.
ASTM D6556
◉
METHOD MODULE
Bulk Density
Distinguishes pelleted pour density from fluffy-powder bulk density.
ASTM D1513 / IC SOP
◉
METHOD MODULE
Sieve Residue
Residue determination using the applicable sieve procedure.
ASTM D1514
All eight method modules are available to explore. Each module includes its method basis, equipment, materials, calculation/reporting notes and procedure overview. Use START GUIDED TEST SESSION for the separate interactive recording workflow. Method validation caveats remain identified within the relevant module.
TEST METHOD
Test Method
INTERACTIVE LAB WORKSPACE
Start a Test
Set up today's run. The guided workflow will collect information as you work, calculate results and save the session to the Lab Results register.
GUIDED MODE
01
Configure your test session
Identify the sample, test, operator and testing location before starting.
A session ID is generated automatically. You can pause and resume this run on this device.
GUIDED TEST SESSION
Ash Content
STEP 1 OF 1
Progress saves automatically.
MODULE 03
Lab Results & Records
Register feedstocks, build blend formulations, route tests to internal or external laboratories, and consolidate results against one sample record.
REGISTERED SAMPLES
0Raw materials + blends
TEST RESULT ENTRIES
0All sources and agencies
LAB PARTNERS
0In-house + external
PENDING RESULTS
0Requested / awaiting report
Sample register
Each physical sample receives a unique record. A blend can contain any number of raw-material components.
Test result ledger
Record multiple tests, replicate readings, agencies and in-house results against the same sample.
Laboratories & testing agencies
Maintain a directory of internal testing capability and external laboratories. Select the performing lab for every test entry.
Test register
Standard test names and method references available for sample test requests.
8 METHODS
Data model principle: one sample can have many tests; one test can have multiple result submissions from different laboratories or repeat runs. Results are never overwritten when a second agency reports a value. This preserves comparison and traceability.
New record
Fields marked required must be completed.
TEAM SPACE
Communication
Share an update or ideaVisible to this team on this browser